Item | Heat Pump (온수 바닥 난방+에어컨 터미널)
|
벽걸이형 보일러 + 불소중앙에어컨
|
Safety | Water floor heating: 전기로 구동, 주요 중형 가정용 중앙 에어컨으로 공기 중 저급 열 에너지 사용: 저압 급수 시스템으로 누수 가능성이 적습니다., 그리고 물은 환경친화적이에요, and water leakage has no impact on the human body
|
Wall-mounted boiler: 가스가 완전히 연소되었는지 확인하는 데 필요합니다., 그렇지 않으면 안전사고가 발생하기 쉽습니다.; 에어컨 불소 시스템: 냉매 시스템은 고압 시스템이다, 그래서 누출 가능성이 상대적으로 높습니다., 누출 감지가 어려울 뿐만 아니라, 하지만 냉매가 새면 인체에도 해롭습니다..
|
Comfort | Moisture is not easy to lose, the temperature gradient is small, and the human body feels comfortable
|
After a long time of use, the indoor air is dry, the comfort is low, and it is easy to get air-conditioning disease
|
Energy Saving
|
When the indoor unit can be controlled separately, the compressor can be controlled by start and stop when the system is under partial load, and the cold/heat storage function of the water system can be used to avoid unnecessary energy consumption
|
At partial load, avoid unnecessary energy consumption by adjusting the speed of the variable frequency compressor or starting and stopping the fixed frequency compressor
|
Heating/cooling effect
|
Air-conditioning floor heating cooling/heating speed is slow and gradually heats up
|
The cooling/heating speed is fast, and it is easy to suddenly cold and hot
|
Reliability
|
With antifreeze protection, power-off memory, intelligent defrosting and other functions to ensure that the unit can operate normally under any circumstances
|
Wall-mounted boilers are greatly affected by gas pressure, and will be limited in places where natural gas is insufficient
|
Air conditioning air
|
15°C~18°C, the human body feels mild
|
7°C~12°C, the temperature of the air outlet is low, and the human body feels cold
|
Design flexibility
|
1. The water system pipeline not limited by the length and height;
2. When multiple units are connected in parallel, the water system can be shared; 3. In cold areas, it can share a set indoor terminal unit with the urban heating pipe network providing heating service in winter
|
1. The length and height difference of the refrigerant piping system are subject to certain restrictions;
2. Two different refrigerant systems cannot be shared; 3. The indoor terminal unit can’t be shared with the urban heating pipe network.
|
Circulating medium
|
Water, which is environmentally safe and has no impact on the environment | Freon, which destroys the ozone layer
|
Service life
|
The design life is as long as 20 years. Cleaning the water pipe improves the life and facilitates maintenance.
|
The general service life is 12 years, and the service life of the fluorine system is 15 years
|
Maintenance
|
All the units use common parts, and the spare parts needed for maintenance can always be purchased in the market
|
In the installation and maintenance project, a large number of specified accessories need to be used, and the systems of different brands can’t match each other
|
포스트 시간: 2023-02-14