Usporedba toplinske pumpe zraka za ultra niske temperature i zidnog kotla + Centralni klima uređaj s fluorom

Usporedba toplinske pumpe zraka za ultra niske temperature i zidnog kotla + Centralni klima uređaj s fluorom

Item Heat Pump (Podno vodeno grijanje+terminal za klimu)

Zidni bojler + Centralni klima uređaj s fluorom

Safety Water floor heating: Pogon na struju, s niskom toplinskom energijom u zraku kao glavni srednji kućni centralni klima uređaj: Manje je vjerojatno da će sustav s niskotlačnom vodom curiti, a voda je ekološki prihvatljiva, and water leakage has no impact on the human body

Wall-mounted boiler: potrebno kako bi se osiguralo da plin potpuno izgori, inače će lako doći do sigurnosnih nezgoda; klimatizacijski sustav s fluorom: sustav rashladnog sredstva je visokotlačni sustav, pa je mogućnost istjecanja relativno velika, ne samo da je teško otkriti curenje, ali i štetno za ljudski organizam ako rashladno sredstvo iscuri.

Comfort Moisture is not easy to lose, the temperature gradient is small, and the human body feels comfortable

After a long time of use, the indoor air is dry, the comfort is low, and it is easy to get air-conditioning disease

Energy Saving

When the indoor unit can be controlled separately, the compressor can be controlled by start and stop when the system is under partial load, and the cold/heat storage function of the water system can be used to avoid unnecessary energy consumption

At partial load, avoid unnecessary energy consumption by adjusting the speed of the variable frequency compressor or starting and stopping the fixed frequency compressor

Heating/cooling effect

Air-conditioning floor heating cooling/heating speed is slow and gradually heats up

The cooling/heating speed is fast, and it is easy to suddenly cold and hot

Reliability

With antifreeze protection, power-off memory, intelligent defrosting and other functions to ensure that the unit can operate normally under any circumstances

Wall-mounted boilers are greatly affected by gas pressure, and will be limited in places where natural gas is insufficient

 

Air conditioning air

15°C~18°C, the human body feels mild

7°C~12°C, the temperature of the air outlet is low, and the human body feels cold

Design flexibility

1. The water system pipeline not limited by the length and height;

2. When multiple units are connected in parallel, the water system can be shared;

3. In cold areas, it can share a set indoor terminal unit with the urban heating pipe network

providing heating service in winter

1. The length and height difference of the refrigerant piping system are subject to certain restrictions;

2. Two different refrigerant systems cannot be shared;

3. The indoor terminal unit can’t be shared with the urban heating pipe network.

Circulating medium

Water, which is environmentally safe and has no impact on the environment Freon, which destroys the ozone layer

Service life

The design life is as long as 20 godine. Cleaning the water pipe improves the life and facilitates maintenance.

The general service life is 12 godine, and the service life of the fluorine system is 15 godine

Maintenance

All the units use common parts, and the spare parts needed for maintenance can always be purchased in the market

In the installation and maintenance project, a large number of specified accessories need to be used, and the systems of different brands can’t match each other


Vrijeme objave: 2023-02-14